Stent Material -: Surgical Grade Cobalt chromium (L605), laser cut from seamless tubing in a serpentine pattern coated with a polymer and Sirolimus mixture.
Amber™ offers high performance in delivering various devices through it by virtue of its inner PTFE lining which is highly lubricious
Multi-segment design of device which makes it maximum kink resistant, offers high level flexibility for gentle cannulation and great torquability from hub to distal end of Catheter
3 layered construction
Flat Stainless-Steel braiding
Relatively larger inner lumen for better space for device delivery
Outstanding kissing Balloon Capabilities
Optimal balance and superior vessel alignment
Excellent backup support
Smooth surface finish to prevent vascular spasm
Atraumatic soft tip to minimize vessel damage
Excellent radio-opacity
Length: 100 cm / 110 cm; with or without side holes
The WIZARD Guidewire is specialized & precoated with PTFE before guidewire assembling that gives smooth texture to WIZARD’s surface to minimize the friction that reduces blood cloth. It has rotating & luer lock flush port that gives easy connections for syringe and available with Safety Cover for Unwanted Hazard Damage. Wizard is a complete range of guidewire, intended for use of introduction spring winding with standard & special sizes, having small diameter with less grinding, special forming tip in J, Straight, Angle & other shape with depth marking. Because of Pre-Coating of PTFE on wire, less force requires for wire passage through catheter. Kink free WIZRAD, PTFE coated guidewires has accurate measurement for catheter tracking. J straightener facilitates easy and smooth movement of the WIZARD & finger straightener that does not require reloading of J Straightener. The Wizard has Better Radiopaque Performance.
he WIZARD PTFE Coated Guidewires Range
Post Coated PTFE Guidewire
Pre Coated PTFE Guidewire
Hydrophilic Coated Guidewire
Nitinol Core Guidewire
Lunderquiest Guidewire
The WIZARD PTFE Guidewire is intended for percutaneous acess of vascular system during PTCA procedure.
Mystent-S is an amalgam of High radial strength & good healing power as it is a combination of Cobalt Chromium and Sirolimus
Intelligent unique stent design gives a high degree of flexibility, excellent scaffolding, lesser chances of recoil, foreshortening and high radial strength
Time tested sirolimus drug and bio-compatible polymer combination, timed to release in 30-40 days
Innovative combination of Axiostat with the conventional compression bands can be used very efficiently to achieve patent haemostasis with zero arterial occlusions. The biologically active Axiostat combined with low pressure by compression band makes it a 2-step simple process of application and removal as compared to conventional multi step application and reduction of pressure in traditional bands for long hours.
Designed with easy-to-grip handles and clear polycarbonate bodies for visibility & durability.
High & Medium Pressure Stopcocks and Manifolds withstand 500 to 1200 psi.
Medium & Low Pressure Stopcocks and Manifolds withstand 250 to 500 psi.
Airless rotator increases chance of successful procedure by minimizing the possibility of air trapping and creates more space for clinician to operate.