Location India, United Arab Emirates, Afghanistan, Antigua and Barbuda, Anguilla, Angola, Bolivia, Bhutan, Botswana, Congo, Chile, Costa Rica, Dominican Republic, Ecuador, Guatemala, Guyana, Honduras, Haiti, Iraq, Jamaica, Kenya, Cayman Islands, Kazakhstan, Libyan Arab Jamahiriya, Madagascar, Myanmar, Mauritania, Mauritius, Maldives, Mozambique, Niger, Nigeria, Nepal, Panama, Peru, St. Pierre and Miquelon, Paraguay, St. Helena, Suriname, El Salvador, Trinidad and Tobago, Tanzania, United Republic of, Venezuela, Vanuatu
Maquet Cardiosave Hybrid Features

The Maquet Cardiosave Hybrid is an intra-aortic balloon pump that can be used in both a transport mode and a hospital setting. The Cardiosave Hybrid offers an improved user interface along with other enhanced features including improvements to algorithms. These advancements allow the balloon to stay inflated longer during procedures. The Large LCD screen allows you to view waveforms with an easy to use navigation and customizable controls.

  • Enhanced pacer detection
  • Sophisticated management of lead faults
  • Advanced triggering performance
  • Backlit monitor and touchscreen control display
  • Color-coded and keyed connections
  • Significantly quieter when compared to earlier generation Maquet/Datascope IABPs
  • Out-of-sight helium tank compartment

 

Maquet Cardiosave Hybrid Specifications Physical
  • Display Closed
    • Height: 44 in (111.8 cm)
    • Width: 22 in ( 59.9 cm)
    • Depth: 27 in (68.6 cm)
  • Display Open 90°
    • Height: 53 in (134.6 cm)
    • Width: 22 in ( 59.9 cm)
    • Depth: 27 in (68.6 cm)
  • Weight
    • Including console, cart, control monitor, helium tank, and 2 batteries
    • 114 lb (51.8 kg)
Operating Ambient
  • Operating Temperature: 50° – 104°F (10° – 40°C)
  • Operating Humidity: 15% to 85% Relative Humidity (non-condensing)
  • Operating Altitude
    • 1060 hPa to 644 hPa (381.0 m to 3657.6 m)
    • 1250 ft to 12,000 ft (795 mmHg to 483 mmHg)

 

Read More...


Request to Call


Business Type Exporter, Supplier, Trader
Color Grey
Application IABP Machine
Type Intra Aortic Balloon Pump
Power Source Electric
Frequency 50Hz

Preferred Buyer From

Location India, United Arab Emirates, Afghanistan, Antigua and Barbuda, Anguilla, Angola, Bolivia, Bhutan, Botswana, Congo, Chile, Costa Rica, Dominican Republic, Ecuador, Guatemala, Guyana, Honduras, Haiti, Iraq, Jamaica, Kenya, Cayman Islands, Kazakhstan, Libyan Arab Jamahiriya, Madagascar, Myanmar, Mauritania, Mauritius, Maldives, Mozambique, Niger, Nigeria, Nepal, Panama, Peru, St. Pierre and Miquelon, Paraguay, St. Helena, Suriname, El Salvador, Trinidad and Tobago, Tanzania, United Republic of, Venezuela, Vanuatu
Maquet CS100 IABP Features

The Datascope SC 100 is an intra-aortic balloon pump that features Intellasync software. The Maquet Datascope CS100 and the Datascope Cs 100 are the same base system the only difference between them is the software on each unit. The CS100 has the more recently updated software. The Datascope IAPB can be used in an operating room, catheter lab, or critical care setting. The system offers three operation modes; automatic, semi-automatic, and manual, making it easy to switch between modes when needed. The Datascope CS100 offers a foldable and detachable laptop-style display. The color display screen makes it easier for caregivers to adjust the pump and monitor the patient remotely. Another version of the Maquet Datascope Intra-Aortic Balloon Pump is the Maquet Datascope CS 300.

  • Maquet CS100 IABP comes with Intellisync and offers a one-button start-up, automatically adapting to changing conditions, making it the right choice for any patient’s condition.
  • Automatically evaluates and selects optimal trigger source and lead
  • Sets inflation at the dicrotic notch and deflates IAB at the start of systole
  • Responds to changes in signal quality by selecting a new trigger source Automated trigger source and timing management to provide continuous, consistent support for your patient.
  • Fast, one-button start-up automatically conducts autofill and initiates 1:1 assist.
  • Full color, high contrast display tilts for easy viewing.<//li>
  • Display and keypad in laptop-style configuration, allowing caregivers to fold and detach the unit for remote operation.
    Easy-to-use keypad with an intuitive user interface.
  • Customizable display panel allows operators to adjust sweep speed, brightness, balloon waveform, and inflation markers.
  • Switch easily between three operation modes: Automatic, Semi-Automatic, and Manual.
  • Automatically evaluates and selects optimal trigger source and lead.
  • The system detects changes and easily adapts to new patient rhythms.
  • Fully annotated printouts with user-configurable waveforms and strip lengths.
  • Locking casters and durable design keep the CS100 secure in a variety of settings.

 

Dimensions
  • Height: 30 in (76.2 cm)
  • Width: 22.5 in (57.2 cm)
  • Depth: 13.2 in (33.5 cm)
  • On Cart
    • Height: 42.2 in (114.8 cm)
    • Width: 17.6 in (44.7 cm)
    • Depth: 23.4 in ( 59.4 cm)
  • Off Cart
    • Height: 28.2 in (71.6 cm)
    • Width: 11.3 in (28.7 cm)
    • Depth: 21.5 in ( 54.6 cm)
  • Monitor weight: 9.5 lb (4.3 kg)
  • Console weight: 133.2 lb ( 60.4 kg)
Color Display
  • Width:8.3 in (21cm)
  • Height: 6.2 in (15.8 cm)
  • viewing angle:
    • Up: 45°
    • Down 55°
    • Right 70°
    • Left 70°
    • Rotates 330°<?li>
    • Tilts180°
  • Detachable Laptop-like closure for storage and protection
Power
  • Mains Voltage: 100-120 VAC ± 10% or 220-240 VAC ± 10%
  • Mains Frequency: 50/60 Hz ± 3 Hz
  • Internal Battery: 24 VDC (nominal), 17.2 Amp-hour, 3 hrs.(approx. @ 90 bpm)
  • Battery Type: Maintenance-free; Sealed lead-acid
General information
  • ECG Gain (default): 1 V output per 1 mV input ±5% (waveform automatically scaled to occupy ECG display window)
  • Gain (variable): 0.15 to 3.0 cm/mV ±20% (autoscaling disabled)
  • Frequency Response: 0.5-12 Hz (display); 0.5-135 Hz (Output to Monitor)
  • Defibrillator Protection: Discharge levels 360 J (trace returns to the screen in 5 sec. max)
Operating Conditions
  • Operating Temperature: 10°C – 40°C
  • Operating Humidity: 5 – 95% (R.H.) non-condensing
  • Operating Altitude: 0 – 12,000 feet (3,657 m); automatic altitude correction for IAB pressure
Operating Modes

 

  • ECG Trigger: Threshold dynamically adjusted by a system for high sensitivity and selectivity of the R-wave detection; Minimum = 120µV ± 20µV at normal gain; 40µV at max. gain
  • Pressure Trigger: The default trigger threshold is automatically adjusted to 38% of the difference between peak systolic and end-diastolic (avg. over multiple cycles); In variable mode: User-adjustable between 7 and 30 mmHg ± 3 mmHg
  • Pacer A Trigger: R-wave detection (as above) except pacer blanking is extended to 100 ms
  • Pacer V/A-V Trigger: V Pacer: fixed at a rate up to 185 bpm (no demand pacing) A-V Pacer: fixed at a rate up to 125 bpm (no demand pacing) with A-V intervals between 80-224 ms
  • Internal Trigger: Variable mode: 40-120 bpm; Normal mode: 80 ± 1 bpm
  • Tall T-Wave Rejection: Rejects all T-Waves where the Q-T interval is <300 ms and the amplitude is <70% of the QRS input amplitude
  • Pacer Rejection: Rejects all pulses of amplitude ± 2.0 mV to ± 700 mV and durations between 0.1 ms to 2.0 ms with 1) No tail; 2) 100 ms time constant tail < 1 mV; 3) 25 ms time constant tail < 1 mV; 4) 4 ms time constant tail < 2 mV
Read More...


Request to Call


Business Type Exporter, Supplier, Trader
Color Grey
Application IABP Machine
Country of Origin India
Power Source Electric
Frequency 50Hz

Preferred Buyer From

Location India, United Arab Emirates, Afghanistan, Antigua and Barbuda, Anguilla, Angola, Bolivia, Bhutan, Botswana, Congo, Chile, Costa Rica, Dominican Republic, Ecuador, Guatemala, Guyana, Honduras, Haiti, Iraq, Jamaica, Kenya, Cayman Islands, Kazakhstan, Libyan Arab Jamahiriya, Madagascar, Myanmar, Mauritania, Mauritius, Maldives, Mozambique, Niger, Nigeria, Nepal, Panama, Peru, St. Pierre and Miquelon, Paraguay, St. Helena, Suriname, El Salvador, Trinidad and Tobago, Tanzania, United Republic of, Venezuela, Vanuatu
Maquet Datascope CS300 Features

The Maquet Datascope CS300 IABP with IntelliSense combines fiber-optic speed with automatic in vivo calibration. The result is a faster time for therapy, faster signal acquisition, and faster adaptation to rate and rhythm changes. Maquet has the only fiber-optic IABP and catheter system that automatically calibrates in the patient after insertion and automatically recalibrates in vivo every two hours or sooner should the patient or environmental conditions change.

The CS300 Datascope IABP with IntelliSense software is designed to emulate an experienced user, allowing you more time to focus on your patient. This sophisticated algorithm automatically selects the best lead and trigger source, sets optimal inflation and deflation timing, and still allows the clinician the
ability to fine-tune deflation timing. The Maquet IABP quickly adapts to rate or rhythm changes in order to optimize augmentation and support during diastole. Another version of the Maquet Datascope Intra-Aortic Balloon Pump is the Maquet Datascope CS 100

  • Faster inflation and deflation speed
  • CS300 has true one-button start-up
  • Automatically calibrates the fiber-optic pressure sensor in the patient and recalibrates every 2 hours or sooner should patient or environmental conditions change
  • Automatically evaluates and selects the best lead and trigger source
  • Automatically sets optimal timing
  • Automatically adjusts to changes in patient conditions without clinician intervention
  • A Maquet fiber-optic IAB catheter
  • Conventional fluid-filled IAB catheters

 

Dimensions
  • Size on Cart: 43.1” H x 22.3” D x 16.8” W (109 cm H x 56.6 cm D x 42.7 cm W)
  • Size off Cart: 26.9” H x 20.5” D x 10.8” W (68.3 cm H x 52.1 cm D x 27.4 cm W)
  • Console Weight: 84.8 lbs. (38.4 Kg) nominal (includes S.D., CRM, and He tank)
  • Monitor: 9.5 lbs. (4.3 Kg) nominal
  • Hospital Cart Weight: 52.4 lbs. (23.8 Kg) nominal
  • Internal Battery: 34 lbs. (15.4 Kg) nominal
  • Storage Bag: 4.6 lbs. (2.1 Kg) nominal (includes doppler and doppler holder))
Color Display
  • Color TFT Liquid Crystal Display (LCD) 8.3”(21cm)W x 6.2”(15.8cm)H; up 45°, 10.4” diagonal (26.4 cm) down 55°, right 70°, left 70° viewing angle; Rotates 330°; Tilts 180°; Detachable; Laptop-like closure for storage and protection; Remote monitor mount (optional)
Trigger
  • ECG Trigger: Threshold dynamically adjusted by the system for high sensitivity and selectivity of the R-wave detection; Minimum = 120µV ± 20µV at a normal gain; 40µV at max. gain
  • Pressure Trigger: The default trigger threshold is automatically adjusted to 38% of the systolic pulse height; 7 mm minimum
  • Manual threshold mode: User-adjustable between 7 and 30 mmHg ± 3 mmHg
  • Pacer A Trigger: R-wave detection (as above) except pacer blanking is extended to 100 ms
  • Pacer V/A-V Trigger: V Pacer: fixed at a rate up to 185 bpm (no demand pacing)
  • A-V Pacer: fixed at a rate up to 125 bpm (no demand pacing) with A-V intervals between 80-224 ms
Power
  • Mains Voltage: 100-120 VAC ± 10% or 220-240 VAC ± 10%
  • Mains Frequency: 50/60 Hz ± 3 Hz
  • Internal Battery: 24 VDC (nominal), 17.2 Amp-hour, approx. 3 hrs. @ 90 bpm
  • Battery Type: Maintenance-free; Sealed lead-acid
Pressure
  • Pressure Output: (electrically isolated)
  • Pressure Range: 0 to +300 mmHg (minimum)
Operation
  • Op. Temp.: 10°C – 40°C
  • Op. Humidity: 5 – 95% (R.H.) non-condensing
  • Op. Altitude: 0 – 12,000 feet (3,657 m); automatic altitude correction for IAB pressure
ECG

 

  • ECG Leads: In Auto Operation Mode: I, II, III, External In Semi-Auto Mode: I, II, III, AVR, AVL, AVF, V, External (12 lead compatibility)
  • ECG Gain (default): 1 V output per 1 mV input ±5% (waveform automatically scaled to occupy ECG display window)
  • Gain (variable): 0.15 to 3.0 cm/mV ±20% (autoscaling disabled)
  • Frequency Response: 0.5-12 Hz (display); 0.5-135 Hz (Output to External Monitor)
  • Defibrillator Protection: Discharge level = 360 J (trace returns to the screen in 5-sec max)
  • ESIS: Automatic suppression with internal ECG amplifier
Read More...


Request to Call




Looking for Product Name ?

Close

Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us